IPB-5000A – Inverter Power Supply
Inverter Power Unit
Features
-
Grafic display with color screen
-
Grafic monitoring functions
-
Integrated interrupt function welding sequence
-
Numeral limit monitoring
-
Quality inspection
-
Self diagnostic function with error messages
-
Overcurrent detection
Applications
-
Insulated wire welding
-
Spot welding
-
Thermal cut-off
-
Resistance soldering and brazing
-
Resistance welding of small parts
Use
-
Bidrictional and external data communication
-
External welding transformer
-
Small and compact body
-
Easily integrable in systems
-
Air cooling
-
Workpiece control before welding
General
-
Part Number 811.00 023
-
Weld Current Type DC inverter
Electrical Power Supply
- Supply Voltage 3-phase, 200-240V or 380-480V
- Mains Frequency 50 or 60 Hz
Power Data
-
Inverter Frequency 5 kHz
-
Max. Weld Current 6 kA
-
Max. Weld Period 2 x 500 ms
-
Functions
-
Control / Control Mode Constant secondary current and voltage, combination of both, constant power
-
Programmable Weld Schedules 127
-
External Weld Schedules Selection 127; with and without parity
-
No. of Weld Pulses 2
-
Weld Pulse Control Squeeze time, resistance precheck, upslope, welding pulse 1 and 2,
downslope, cooling time, hold time -
Counter Output signal when presettings are reached:
Total counter, good product counter, work piece counter -
Up-Slope Time with / without
2 / 3
Setting Ranges
-
Current range 0.2 – 2 kA; 0.4 – 4 kA; 0.6 – 6 kA (dependent on weld transformer)
-
Voltage Range 0.30 – 9.99 V
-
Power range 0.2 – 20 kW
-
Signal Processing No Good: to choice break or make contact
-
Output Signal Activation 10 / 100 ms; auomatically or until start signal becomes inactive
-
Counter Default 000000 – 999999
Time Settings
-
Squeeze Time 0000 – 9999 ms
-
Resistance Checking 0.00 – 9.99 ms
-
Up-Slope Time Upslope 1 and 2: 000.0 – 500.0 ms
-
Start Signal Stabilisation Time Presetting: 1 – 5 – 10 – 20 ms
-
Weld Pulse Pulse 1 and 2: 000,0 – 500,0 ms
-
Delay Time after end of welding current to monitoring of penetration
-
Down-slope Time Downslope 1 and 2: 000.0 – 500.0 ms
-
Hold Time after downslope: 0 – 999 ms
-
Cooling Period between pulse 1 and 2: 00.0 – 99.8
Distance Measurement
-
Displacement Measuring Range max. 30 mm
-
Penetration Lower and upper limit of numeral penetration after
welding from +29,999 to -29,999 mm -
Penetration Measurement Accuracy Resolution of diplacement sensor: 1 μm
Monitoring Functions
-
Measured Parameters Pulse width, weld time, penetration, current, voltage, resistance
-
Limit Values Lower and upper limit of current, voltage, power, penetration
-
Part Detection Before welding: Work piece available resp. Electrode
in accordance to limit window (+29,999 bis -29,999 mm) -
Weld Abort Jump when presetted penetration is reached:
1st pulse to cooling time, 2nd pulse to hold time -
Numeral Limits Current, voltage, power, resistance, weld time, penetration
-
Graphic Limits Current or voltage; power, resistance, penetration
-
Envelope Waveform Grafic monitoring of a value
-
Up-Slope with or without monitoring
-
Weld Current Monitoring delay time 00 – 10 ms
Interfaces
-
Serial Interface RS232 or RS 485
Mechanical Data
-
Dimensions 269 x 172 x 390 (H x W x D)
-
Weight 15 kg
Operation Data
-
Ambient Temperature 5 – 40° C
-
Humidity < 90% (no condensation)
-
Cooling air-cooled
Transformer
-
Weld Transformer external
-
Transformer Type e.g. ITB-780A6
Accessory
-
Penetration Sensor all as an option: GS-1630A (Ono Sokki); GS-1631A (Ono Sokki);
with conversion cable: (Mitutoyo); ST-1278 (Heidenhain) -
3 / 3